Internet of Things (IoT) Based Air Pollution Detector for Baby Rooms

Authors

  • Najmawatih Universitas Handayani Makassar
  • Imran Taufik Universitas Handayani Makassar
  • Supriadi Universitas Handayani Makassar
  • Anders Christensen University of Western Australia

Keywords:

Indoor Air Pollution, Infant Room Monitoring, Internet of Things (IoT), Real-Time Notification System, PM2.5 and Carbon Monoxide Detection
doi https://doi.org/10.56134/jst.v4i1.111

Abstract

Indoor air pollution is a leading cause of respiratory illnesses in infants and children, potentially resulting in severe health outcomes, including death. Common sources include dust, cigarette smoke, cleaning chemicals, and hazardous gases such as carbon monoxide (CO) and nitrogen dioxide (NO₂), particularly in enclosed, air-conditioned (AC) environments. Due to the difficulty of detecting pollutants like fine particulate matter (PM2.5) and CO, an effective, real-time monitoring solution is crucial. This study aims to design and develop an Internet of Things (IoT)-based device capable of monitoring PM2.5, CO, temperature, and humidity, specifically in infant rooms. The system integrates an ESP32 microcontroller with DSM501a, MQ-7, and DHT22 sensors and features automated alerts via a Telegram bot when pollutant levels exceed predefined thresholds. The device was evaluated through a comparative 24/7 testing method over seven days against commercially available standard instruments. Results show a relative error of 25% for PM2.5, 30% for CO, and significantly lower errors for temperature (2%) and humidity (0%). Sensor data is processed and transmitted to the Thingspeak server for real-time graphical monitoring. The Telegram alert feature demonstrated an average response time of 1.84 seconds across 20 tests. The findings suggest that the proposed device offers a viable, accessible, and responsive solution for indoor pollutant detection, contributing to improved air quality monitoring and early warning systems to protect vulnerable populations, especially infants.

Downloads

Download data is not yet available.

References

Administrator. (2024). Dampak Pengunaan AC Untuk Bayi. Bengkeltv.Id.

Adminlp2m. (2022, June). Metode Waterfall.

Aji, N. S. (2024). Polusi Udara di Perkotaan, Penyebab, Dampak, dan Solusi yang Dapat Dilakukan. Bangkalan.Pikiran-Rakyat.Com.

Azka. (2023). Karbon Monoksida: Penyebab, Bahaya, dan Cara Mengatasinya. Tekniksipil.Id.

Borecky, J., Kohlik, M., & Kubátová, H. (2016). Parity Waterfall Method. 2016 IEEE 19th International Symposium on Design and Diagnostics of Electronic Circuits & Systems (DDECS), 1–6.

Elektronika, W. (2024). Rangkaian Elektronika: Pengertian, Fungsi, Contoh Skema. Wikielektronika.Com.

Ersyandhy, M. (2024). Thingspeak. Caepisan ID.

Fadila, I., & Upahita, D. (2024). Polusi Udara dalam Ruangan, Ini Penyebab dan Bahayanya. Hellosehat.Com.

Forbes, Guardian, & Aminullah, M. (2020). Polusi Udara Turut Andil dalam Kematian Hampir 500 Ribu Bayi pada 2019. Tempo.Co.

Garmini, R., & Purwana, R. (2020). Polusi udara dalam rumah terhadap infeksi saluran pernafasan akut pada balita di tpa sukawinatan palembang. Jurnal Kesehatan Lingkungan Indonesia, 19(1), 1.

Handayani, V. V. (2020). Pengaruh Polusi Udara pada Kesehatan. Www.Halodoc.Com.

Haryanto, B. (2018). Climate Change and Urban Air Pollution Health Impacts in Indonesia.

Iqbal. (2023). Apa Itu Metode Waterfall Serta Kelebihan, Kekurangan dan Tahapannya. Nextgen.Co.Id.

Kav, R. M. (2024). Polusi Udara. Www.Safetysign.Co.Id.

la Iglesia, D. H., De Paz, J. F., Villarrubia Gonzalez, G., Barriuso, A. L., & Bajo, J. (2018). A context-aware indoor air quality system for sudden infant death syndrome prevention. Sensors, 18(3), 757. https://doi.org/https://doi.org/10.3390/s18030757

Lumbangaol, S., Siagian, R., Siahaan, F., & Sitinjak, E. (2022). IOT-Based Pollution and Air Quality Monitoring Equipment with ESP-8266. Batusangkar International. https://doi.org/https://doi.org/10.4108/eai.11-10-2021.2319568

Maydiantoro, A. (2021). Model-model penelitian pengembangan (research and development). Jurnal Pengembangan Profesi Pendidik Indonesia (JPPPI).

Meilinaeka. (2023). Metode Waterfall dalam Pengembangan Perangkat Lunak. Telkomuniversity.

Mukaromah, V. fadhrotul, & Nugroho, R. S. (2020). Riset: 500.000 Bayi Meninggal dalam Setahun karena Polusi Udara. Kompas.Com.

Mukono, H. J. (2011). Aspek kesehatan pencemaran udara. Airlangga University Press.

Nettikadan, D., Raj, S., & others. (2018). Smart community monitoring system using Thingspeak IoT platform. International Journal of Applied Engineering Research, 13(17), 13402–13408.

Noviarni, S. (2020). Ratusan Ribu Bayi Meninggal Akibat Polusi Udara. Lifestyle.Sindonews.Com.

Nugraha, R. M., & Bhwana, P. G. (2021). Indonesia in Top 10 Countries with Worst Air Quality. En.Tempo.Co.

Pimprale, V., Arora, S., & Deshmukh, N. (2023). IoT Cloud Platforms: A Case Study in ThingSpeak IoT Platform. In Integration of Cloud Computing with Emerging Technologies (pp. 182–198). CRC Press.

Prasasti, G. D. (2020). Hampir Setengah Juta Bayi di Dunia Meninggal Akibat Polusi Udara. Liputan6.Com.

Prasetyo, W. W. (2023). Pengertian Dasar Karbon Monoksida (CO) dan Dampaknya pada Kesehatan Manusia. Blog.Cems.Id.

Prasetyo, W. W. (2024). Pemahaman Mendalam tentang PM2.5: Sumber, Dampak, dan Solusi. Blog.Cems.Id.

Priyana, Y. (2023). Studi Kausalitas antara Polusi Udara dan Kejadian Penyakit Saluran Pernapasan pada Penduduk Kota Bogor, Jawa Barat, Indonesia. Jurnal Multidisiplin West Science.

Puskomedia. (2024). Kontrol Parental vs. Pengawasan Orang Tua: Perbedaan dan Persamaan. PuskoMedia Indonesia.

Putra, N. (2012). Research development: penelitian dan pengembangan suatu pengantar.

Putrikrislia, U. P. (2021). Bahaya AC untuk Bayi dan Tips Menggunakannya. Doktersehat.Com.

Rafsanjani, A. I. (2021). Polusi Udara.

RF, N., & Oktaviani, D. Y. (2024). Bahaya Polusi Udara dalam Ruangan. Www.Idntimes.Com.

Rivaldi, F., Maulana, R., & Ichsan, M. H. H. (2022). Sistem Deteksi Pencemaran Gas Beracun CO, HC, NOx dalam Ruangan Tertutup dengan Metode Support Vector Machine. Jurnal Pengembangan Teknologi Informasi Dan Ilmu Komputer, 6(8), 4033–4038.

Rosário Filho, N. A., Urrutia-Pereira, M., D’Amato, G., Cecchi, L., Ansotegui, I. J., Galán, C., Pomés, A., Murrieta-Aguttes, M., Caraballo, L., Rouadi, P., & others. (2021). Air pollution and indoor settings. World Allergy Organization Journal, 14(1), 100499. https://doi.org/https://doi.org/10.1016/j.waojou.2020.100499

Rosyidah, M. (2018). Polusi Udara dan Kesehatan Pernafasan.

Safitri, V. A., Sari, L., & Gamayuni, R. R. (2020). Research and Development (R&D), environmental investments, to eco-efficiency, and firm value. The Indonesian Journal of Accounting Research, 22(3). https://doi.org/https://doi.org/10.33312/ijar.446

Saidal Siburian, M. M., & Mar, M. (2020). Pencemaran Udara dan Emisi Gas Rumah Kaca. Kreasi Cendekia Pustaka.

Salim, M. P. (2023). CO adalah Karbon Monoksida, Pahami Sifat dan Bahayanya bagi Manusia. Liputan6.Com.

Sari, Y., & Waliyuddin, A. (2021). Alat Deteksi Polusi Udara Dalam Ruangan Berbasis Internet Of Things (IOT). Jurnal Ilmiah Teknik Informatika (TEKINFO), 22(2), 120–134. https://doi.org/https://doi.org/10.37817/tekinfo.v22i2.1768

Senarath, U. S. (2021). Waterfall methodology, prototyping and agile development. Tech Rep, 1–16.

Sendari, S., Hadi, M. S., Rahmawati, Y., Hadi, N. C., Wibowo, F. S., Wibowo, D. A., Agustin, W., Kumalasari, I., Rachman, I., & Matsumoto, T. (2019). Design and analysis of safety hazardous gas instruments for laboratory experiments. AIP Conference Proceedings, 2173(1).

Suhartawan, B., & MT, M. (2024). Kualitas Udara. Pengantar Teknik Lingkungan, 15.

Tagliafico, J. (2021). Diagram Skematik. Www.Yubrain.Com.

Taufiqullah. (2024). Sistem Kendali Manual dan Otomatis. Www.Tneutron.Net.

Tekno. (2021). Metode Waterfall Menurut Para Ahli, Begini Penjelasannya. Kumparan.Com.

Tunashijau. (2024). Polusi Udara bagi Kesehatan: Dampak, Penyebab dan Pencegahannya. Tunas Hijau ID.

Yasir, M. W. (2021). Pencemaran Udara di Perkotaan Berdampak Bahaya Bagi Manusia, Hewan, Tumbuhan dan Bangunan.

Yunus, F. (2004). Cermin Dunia Kedokteran.

Yuwono, T. A. (2008). Faktor-faktor lingkungan fisik rumah yang Berhubungan dengan kejadian pneumonia pada Anak balita di wilayah kerja puskesmas Kawunganten kabupaten cilacap. Program Pasca Sarjana Universitas Diponegoro.

Published

2025-04-22
CITATION
DOI: 10.56134/jst.v4i1.111
Published: 2025-04-22

How to Cite

Najmawatih, Imran Taufik, Supriadi, & Anders Christensen. (2025). Internet of Things (IoT) Based Air Pollution Detector for Baby Rooms. Ceddi Journal of Information System and Technology (JST), 4(1), 40–51. https://doi.org/10.56134/jst.v4i1.111

Issue

Section

Articles